 PAM HYDRO-2 connected to a P-2 correlator transmiter
PAM HYDRO Hydrophones for plastic pipes
Download brochure ..
Description
Hydrophones are very sensitive sensors for correlation
and made especially for the hard circumstances
on plastic pipes or large diameters.
Hydrophones are directly connected to the water
column. Hydrants are the common connection
points but any other connection like taps in houses
are probable.
SebaKMT hydrophones feature a high sensitivity
especially in the lower frequency band. Because of
that they are very appropriate for correlation on
plastic pipes, pipes with a long distance or larger
diameter.
The handling is very easy and allows a quick mounting
to hydrants below and beneath the ground.
A de-aeration valve on the top of the hydrophone is
used to comfortably carry out the ventilation of the
sensors.
Scope of delivery
- 2 x PAM HYDRO-2 hydrophones
- 1 x AD HYDRO-2 hydrant key adapter
- 2 x Connection lead
- 2 x De-aeration hose
- 1 x Transport case
- Div. adapter
Technical Data
PAM HYDRO-2
Dimensions: 110 x 96 mm Ø
Weight: ca. 1 Kg
IP protection class: IP 68
Operation temperature: -20 - +70 °C
Storage temperature: -20 - +70 °C
Power supply: Via correlator transmitter
Interface: Cable to correlator transmitter
Sensitivity: -201 db
Frequency range: 0 - 1000 Hz
Connectors: 2” thread incl. adapters
|